STANFORD RESEARCH SYSTEMS DS360 CALIBRATION and STANFORD RESEARCH SYSTEMS DS360 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the STANFORD RESEARCH SYSTEMS DS360 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Function Generator?
Shop for Comparable Products on our
 used Function Generator page or new Function Generator page

 
   STANFORD RESEARCH SYSTEMS DS360   Description / Specification:   Spec Sheet 
STANFORD RESEARCH SYSTEMS DS360 200 kHz Ultra-low Distortion Function Generator

The SRS DS360 Ultra-low distortion function generator has less than 0.001 % total harmonic distortion (THD), 25 ppm frequency accuracy, and a broad range of features including sweeps and bursts. The DS360 uses digital signal processing and a precision 20-bit D/A converter to provide better than –100 dB distortion over the audio frequency range. With its DDS architecture, the DS360 has the features and flexibility of a contemporary synthesized function generator. Careful shielding and board layout keep the output noise to a minimum, making the DS360 the instrument of choice for audio research and development, manufacturing, and automated testing. It has 6-digit frequency resolution from 1 mHz to 200 kHz, and a steady 25 ppm frequency stability. Specifications. Sine Frequency range: 0.01 Hz to 200.000 kHz. Square Frequency range: 0.01 Hz to 200 kHz. Rise time 1.3 µs. White Noise Bandwidth: DC to 200 kHz. Flatness: <1.0 dB, 1 Hz to 100 kHz. Pink Noise Bandwidth: 10 Hz to 200 kHz. Flatness: <3.0 dB (20 Hz to 20 kHz) (measured using 1/3 oct. analysis). Two-Tone Type: Sine-sine, sine-square. Sine or Square Burst On cycles: 0.5, 1 to 65534 cycles. Repetition rate: 1 to 65535 cycles. Frequency Resolution: 6 digits or 10 mHz (whichever is greater). Frequency Accuracy: 25 ppm (0.0025 %) + 4 mHz (20 °C to 40 °C). Amplitude Unbalanced outputs: 5.0 µVpp to 14.4 Vpp (50 ohm load). Amplitude Balanced outputs: 10.0 µVpp to 28.8 Vpp (50 ohm load). Resolution: 4 digits or 1 µV, whichever is greater (Vpp or Vrms), 0.1 dB (dBm or dBV). Computer interfaces: GPIB and RS-232. All instrument functions can be controlled. Option 03 10 MHz reference input.



 

Standard Calibration $515.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the STANFORD RESEARCH SYSTEMS DS360. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Bandwidth
Bandwidth is the difference between the upper and lower frequencies in a contiguous set of frequencies within which a component, link or network will operate.

Frequency Span
Frequency Span specifies the range between the start and stop frequencies, also referred to as bandwidth

Noise Figure
Noise Figure the ratio of the signal-to-noise power ratio at the input to the signal-to-noise power ratio at the output.

Ringing
Ringing is an unwanted oscillation of a voltage or current.


Please contact us for your STANFORD RESEARCH SYSTEMS DS360 CALIBRATION and/or STANFORD RESEARCH SYSTEMS DS360 200 kHz Ultra-low Distortion Function Generator REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: